Introduction
Built with a new aluminum alloy die-casting process, the QHVT-10ZD/50ZD digital Vickers and Knoop hardness tester boasts a sturdy, stable housing with a sleek, modern design. Its direct drive loading mechanism ensures consistent force application and high testing throughput. The unit comes with two indenters and four objectives that feature automatic recognition and switching, making it adaptable to a variety of testing scenarios.
A digital eyepiece works in conjunction with the touch screen to clearly display test force, indentation length, dwell time, conversion scale, date, and time. Operation is straightforward: after measuring the indentation, simply press the eyepiece button, and the hardness value is automatically calculated and shown on the screen.

- Crafted with a new aluminum alloy die-casting process, the main body is sturdy, stable, and visually appealing.
- Crafted from a specialized material and heat-treated to 35–40HRC, the lifting screw offers exceptional wear resistance. The worm gear and worm structure further ensures smooth, stable lifting operation.
- The closed-loop load cell loading system, combined with a direct-drive motor that applies test force vertically, provides exceptionally stable performance.
- The turret's rapid rotation significantly enhances overall testing productivity.
- The loading and turret motors are both imported, ensuring superior build quality, low noise levels, and reliable stability.
- The modular cover design of the machine body ensures hassle-free maintenance.
- With a six-station turret that holds Vickers and Knoop dual indenters and 5X/10X/20X/40X objectives, the instrument automatically identifies and switches between them for seamless operation.
- The turret switching system integrates mechanical and photoelectric limits, providing superior positioning accuracy to maintain precise six-point-one-center alignment.
- The LED light source delivers superior durability for prolonged use.
- The 8-inch HD color touch screen features an adjustable angle, making operation more comfortable and user-friendly.
- With Vickers and Knoop testing modes built in, the system allows for real-time conversion between various hardness scales and convenient on-demand switching.
- The system allows for upper and lower limit configuration, delivering clear prompts whenever test results exceed the specified tolerance.
- The instrument offers real-time storage of hardness test results, with functionality for data classification and selective deletion. Automatic calculation of maximum, minimum, and average values is provided. Furthermore, an RS232 interface is included to facilitate PC connectivity for data output.
Application Range
This equipment is suitable for a broad spectrum of materials: ferrous and non-ferrous metals, IC thin sections, coatings, ply-metals, glass, ceramics, agate, precious stones, and thin plastic sections. It is also applicable for hardness testing of carbonized layers and quench-hardened layers, with capabilities to evaluate both depth and trapezoidal profiles.
Detail Pictures


Technical Parameters
|
Model |
QHVT-10ZD |
QHVT-50ZD |
|
|
Test Force |
kgf |
0.3kgf, 0.5kgf, 1kgf, 2kgf, 2.5kgf, 3kgf, 5kgf, 10kgf |
0.5kgf, 1kgf, 2kgf, 2.5kgf, 3kgf, 5kgf, 10kgf, 20kgf, 30kgf, 50kgf |
|
N |
2.94N, 4.90N, 9.80N, 19.6N, 24.5N, 29.4N, 49N, 98N |
4.90N, 9.80N, 19.6N, 24.5N, 29.4N, 49N, 98N, 196N, 294N, 490N |
|
|
Test Mode |
HV/HK |
||
|
Test Range |
1HV~3000HV |
||
|
Hardness Resolution |
0.1HV |
||
|
Loading Method |
Automatic (Loading/Dwell/Unloading) |
||
|
Turret |
Automatic Shifting |
||
|
Data Output |
RS232 Interface |
||
|
Hardness Reading |
8 inch Color Touch Screen, Automatic Data Storage |
||
|
Conversion Scale |
HRA, HRBW, HRC, HRD, HREW, HRFW, HRGW, HRHW, HRKW, HR15N, HR30N, HR45N, HR15TW, HR30TW, HR45TW, HV, HK, HS, HBS, HBW, HLD |
||
|
Data Storage |
6 folders, each 1000 sets data |
||
|
Eyepiece |
10× Digital Measuring Eyepiece |
||
|
Objective |
5×,10×,20×,40× |
||
|
Total Magnification |
50×,100×,200×,400× |
||
|
Effective Field of View |
5×:1.6mm,10×:800μm,20×:400μm,40×:200μm |
||
|
Min. Measuring Unit |
5×:0.5μm,10×:0.25μm,20×:0.13μm,40×:0.06μm |
||
|
Dwell Time |
0~99s |
||
|
Light Source |
LED |
||
|
Digital X-Y Test Table |
Size: 120×120mm; Travel: 25×25mm; Resolution: 0.001mm |
||
|
Max. Sample Height |
175mm |
||
|
Throat Depth |
140mm |
||
|
Power Supply |
AC220V,50Hz |
||
|
Execute Standard |
GB/T 4340,ISO 6507,ASTM E92,JIS Z2244 |
||
|
Dimension |
495×575×670mm |
||
|
Net Weight |
35kg |
||
Packing List
|
Name |
Qty |
Name |
Qty |
|
Instrument Main Body |
1 set |
Accessory Box |
1 pc |
|
10× Digital Measuring Eyepiece |
1 pc |
Digital X-Y Test Table |
1 pc |
|
Standard Vickers Hardness Block |
2 pcs |
Standard Knoop Hardness Block |
1 pcs |
|
Horizontal Regulating Screw |
4 pcs |
Level |
1 pc |
|
Inner Hexagon Spanner 2.5mm, 3mm |
each 1 pc |
Screw Driver |
2 pcs |
|
Fuse 1A |
2 pcs |
Power Cable |
1 pc |
|
Anti-dust Cover |
1 pc |
Usage Instruction Manual |
1 copy |
FAQ
Q: How should fixtures be selected and maintained?
A: The selection of fixtures depends on the shape, material, and testing type of the sample. We offer a variety of conventional fixtures, and can also customize matching fixtures according to the shape of the sample. During maintenance, it is necessary to keep the fixtures clean, avoid collisions, and regularly apply rust proof oil.
Q: What should be done if abnormal noise or vibration occurs during equipment operation?
A: Please press the emergency stop button immediately to stop the test. Firstly, check if the equipment is placed horizontally and if the sample is placed correctly. If the problem persists, please contact our after-sales service department promptly.
Q: How to perform daily maintenance and upkeep on equipment?
A: Routine maintenance includes: keeping the equipment clean; regularly inspecting transmission components and adding appropriate lubricant; avoiding overloading the equipment; and periodically powering it on during long-term inactivity. Please refer to the accompanying "User and Maintenance Manual" for specific maintenance cycles and methods.
Hot Tags: two indenters vickers hardness tester, China two indenters vickers hardness tester manufacturers, suppliers, factory